Experiment on Seismic Performance of Circular Concrete Columns Reinforced with HRB500E, HRB600 Steel
Jun-jie WANG,Jun-sheng SU,Wen-biao WANG,Zheng-fang DONG,Bo LIU
DOI: https://doi.org/10.19721/j.cnki.1001-7372.2015.05.005
2015-01-01
Abstract:In order to investigate the effect of high strength steel on seismic performance of concrete circular columns,11 reinforced concrete circular column specimens with HRB335,HRB500E and HRB600 steel were conducted quasi-static tests with reversed cyclic loading.With equal volume and equal strength steel replacement,the effects of longitudinal bar strength,stirrups strength,stirrups spacing and concrete strength on seismic performance,such as failure mechanism,flexural capacity,energy dissipation capacity and displacement ductility were compared and analyzed.The results show that the reinforced columns with different strength steel present typical flexural failure mode where column bottom appears plastic hinge,and longitudinal bar buckles and subsequent fractures.Under equal volume steel replacement,longitudinal bar strength has a great effect on bearing capacity,deformability and energy dissipation of concrete columns,while stirrups strength has a little effect.When high strength steel is used to replace ordinary strength steel with equal strength replacement,the reinforced columns with different strength steel have similar seismic performance,resulting in less steel consumption.With the increase of stirrups spacing,the constraint for longitudinal bar provided by stirrups declines,resulting in the decrease of deformability and energy dissipation capacity of concrete columns.The concrete strength has a little effect on seismic performance of concrete columns.