Sensitive Carbon Monoxide Detection Based on Light-Induced Thermoelastic Spectroscopy with a Fiber-Coupled Multipass Cell [Invited]

Xiaonan Liu,Yufei Ma
DOI: https://doi.org/10.3788/col202220.031201
IF: 2.56
2022-01-01
Chinese Optics Letters
Abstract:A sensor based on light-induced thermoelastic spectroscopy (LITES) with a fiber-coupled multipass cell was demonstrated for carbon monoxide (CO) detection. The fiber-coupled structure has the merits of reducing optical interference and difficulty in optical alignment and increasing system robustness. A 1.57 μm continuous wave distributed feedback diode laser was used as the excitation source. A minimum detection limit of 9 ppm was obtained, and the calculated normalized noise equivalent absorption coefficient was 1.15×10-7 cm-1·W·Hz-1/2. The reported CO-LITES sensor showed excellent linear concentration response and system stability.
What problem does this paper attempt to address?