Quantitative relation between ageing condition of pressboard impregnated in mineral oil and its frequency dielectric response

Hua Wen,Jian Hao,Ruijin Liao,Yaolong Wang,Lei Chen
2011-01-01
Abstract:In order to use the frequency domain spectroscopy (FDS) for assessing the ageing condition of oil-paper insulation in transformers, the accelerated thermal ageing experiment of oil-paper insulation were performed at 130°C,and the oil-paper insulation samples with different ageing state were tested by FDS. The ageing and temperature effects on FDS results were quantified. Research shows that the FDS can reflect the ageing state of the oil-paper insulation. The real part of the relative complex permittivity 'r , dissipation factor tan plots of oil impregnated pressboards with different degree of polymerization (DP) shifts upwards in the lower frequencies range of 10 -3 Hz to 10 -1 Hz with the ageing time increased. The parameters including DP, 'r or tan values at the characteristic frequencies and the ageing time t meet a good exponential relationship. In addition, the 'r and tan curves of aged impregnated pressboard were observed to be shifted upwards to higher values at lower frequencies with the increasing temperature. There is an exponential relationship between the 'r (tanδ) values at the characteristic frequencies and the testing temperature.
What problem does this paper attempt to address?