Return-stroke Current Measurement at the Canton Tower and Preliminary Analysis Results

Lyuwen Chen,Weitao Lyu,Ying Ma,Qi,Bin Wu,Yijun Zhang,Qiyuan Yin,Hengyi Liu,Yang Zhang,Shaodong Chen,Xu Yan,Sai Du
DOI: https://doi.org/10.1016/j.epsr.2022.107798
IF: 3.818
2022-01-01
Electric Power Systems Research
Abstract:The lightning current on the 600-m high Canton Tower was measured directly for the first time, using a Rogowski coil installed at a height of 492 m above ground level. Return-stroke current measurements for three single-stroke downward negative flashes and two multiple-stroke upward negative flashes were presented and preliminarily analysed by combining the associated return-stroke luminosity and data of the lightning location system (LLS). The 10-90% rising time and the full width at half maximum (FWHM) of the first-stroke current were within a range of 6.0 to 9.3 mu s and 68.1 to 96.9 mu s, respectively. Subsequent-stroke currents were characterized by distinct sharp double peaks, and the typical 10-90% rising time of the initial peak was about 0.4 to 0.5 mu s. The FWHM of the subsequent-stroke current ranged from 6.1 to 39.3 mu s with AM (GM) value of 18.1 (15.0) mu s. An approxi-mately quadratic relation was found between the maximum peak current and the initial peak luminosity for subsequent strokes in the same upward flash. A total of 88% (14/16) of the subsequent strokes were misclassified as intracloud (IC) events by the LLS. The LLS-inferred peak current was overestimated by a larger factor for subsequent strokes than the first strokes.
What problem does this paper attempt to address?