Factors Influencing the Removal of Boron from Fracturing Fluid Flowback by Chemical Oxidative Precipitation

Yu T.,He R. R.,Zhang X.,Liu J. X.,Kou B.,Zhang X. F.,Qu C. T.,Huang Y.
DOI: https://doi.org/10.1007/s40034-021-00232-2
2021-01-01
Journal of The Institution of Engineers (India) Series E
Abstract:The reuse of fracturing fluid flowback contributes toward water resource conservation and the reduction of environmental pollution. However, the ability to reuse the flowback is affected by its residual boron content. Hence, the control of boron content is crucial for effective flowback reuse and the reduction of relevant treatment costs. In the present study, chemical oxidation combined with the flocculation precipitation method was used to remove residual boron from fracturing flowback fluid. Taking boron removal rate as an index, the effects of the precipitator, oxidant, pretreatment pH (pHp), n(H2O2)/n(B) value, pretreatment time (tp), n(Ba)/n(B) value, reaction pH (pHr), and reaction time (tr) on boron removal by chemical oxygen precipitation were studied. The results showed that boron removal was performed at 20–25 °C via chemical oxidative precipitation. The use of BaCl2 as the precipitating agent and H2O2 as the oxidizing agent (under the following conditions: pretreatment pH = 9, pretreatment time (tp) = 30 min, reaction pH = 10, and reaction time (tr) = 360 min) led to a boron removal rate of 95.5% and a residual boron content of 6.76 mg/L in the solution.
What problem does this paper attempt to address?