Full-Scale Experiments on Ship Accommodation Cabin Fire

Bosi Zhang,Jiaqing Zhang,Xiaomin Wang,Shouxiang Lu,Changhai Li
DOI: https://doi.org/10.1007/978-981-10-0376-9_51
2016-01-01
Abstract:The fire hazard of an accommodation cabin for sailors on ships was investigated experimentally. The effects of supply air from the air-conditioning system on the fire development were studied. The combustibles were arranged according to a real ship accommodation cabin. The heat release rate (HRR), which is a key parameter for evaluating the fire hazard, was calculated based upon the oxygen consumption method. In addition, the flame behavior and gas temperature were presented. Results showed that fire in the ship accommodation cabin was over-ventilated when the door was open. In no ventilation case, the entire combustibles burst into burning at approximately 230 s after ignition, and the maximum temperature rise of fire smoke was about 860°C. In forced ventilation case, the fire development was slower, and the smoke temperature was apparently lower, compared with those in no ventilation test. This was mainly due to the cooling effect of the supply air on smoke, leading to decrease in the heat transfer to the combustibles. The peak HRRs were about 800 kW and 560 kW, which reached at around 230 s and 400 s after ignition in no ventilation and forced ventilation tests, respectively. The variations of HRR in the growth stage of fires were in accordance with the “t-square fire”. In no ventilation test, the growth factor was 0.0270, while it decreased to 0.0049 in the test with forced supply air.
What problem does this paper attempt to address?