Experimental Study of Transitional Behavior of Fully Developed Under-Ventilated Compartment Fire and Associated Facade Flame Height Evolution

Fei Ren,Longhua Hu,Xiaolei Zhang,Xiepeng Sun,Jianping Zhang,Michael Delichatsios
DOI: https://doi.org/10.1016/j.combustflame.2019.07.003
IF: 4.4
2019-01-01
Combustion and Flame
Abstract:For compartment fires with an opening, two distinct states are widely recognized: well-ventilated (oxygen is sufficient for combustion inside the compartment) and under-ventilated (oxygen is completely used inside the compartment). And as a consequence, the flame ejects out through the opening with excess fuel burning outside when reaching under-ventilated condition. However, in this work, a further transitional behavior of under-ventilated compartment fires with increasing fuel supply is revealed and quantified. Experiments were carried out using an under-ventilated fire compartment (0.4m cubic) with a fixed opening width (0.25 m) and various opening heights (0.0125 m to 0.15 m) (corresponding ventilation factors, A root H, 3.49 x 10(-4) to 1.45 x 10(-2) m(2.5)). The temperature inside the compartment and the facade flame ejected through the opening were recorded with increasing fuel supply (or namely total heat release rate) for under-ventilated conditions. The results showed that when the under-ventilated compartment fire reached a transitional state, the temperature inside the compartment experienced a sudden drop associated with a sudden increase of facade flame height outside the opening, posing a more severe impact on the building facade. The critical fuel supply rate for reaching the transitional state could be divided into two different mechanisms by a critical value of the opening ventilation factor ([0.5A root H]=0.0033 kg/s), based on the mass balance and flame stoichiometric extinction analysis inside the compartment. The formula for describing the critical fuel supply rate by considering the evolution of the critical air-fuel equivalence ratio (chi) for both mechanisms was proposed. The classic model on the facade flame height for common under-ventilated compartment fires was found to be not applicable when the transitional state of under-ventilated condition had been reached. A new model was proposed to correlate the facade flame height for the transitional state of under-ventilated condition, which was shown to have a 2/3 power dependence on the total heat release rate taking the opening width as the characteristic length. (C) 2019 The Combustion Institute. Published by Elsevier Inc. All rights reserved.
What problem does this paper attempt to address?