Full-scale Loading Test for Shield Tunnel Segments: Load-bearing Performance and Failure Patterns of Lining Structures
Gang Wei,Feifan Feng,Shiyu Huang,Tianbao Xu,Jiaxuan Zhu,Xiao Wang,Chengwei Zhu
DOI: https://doi.org/10.1016/j.undsp.2024.05.003
IF: 5.327
2025-01-01
Underground Space
Abstract:To explore the load-bearing performance and the failure patterns of the lining structures, a full-scale loading test on the three-ring staggered assembled shield tunnel segments is carried out through a hydraulic loading system. In the experimental study, the segments' internal force, convergence deformation, and displacement, and the bolts' internal force, are analyzed. According to the experimental results, the relationship between internal force and deformation is obtained to determine the residual bearing capacity of the shield tunnel at each stage. Three stages are specified for the evolution of the segment's maximum bending moment during the loading process, in which, the elastic stage is the main and longest stage, in which the bending moment of the segment increases the most. There are two stages for convergence deformation development and segment misalignment development. At the end of loading, the segment's maximum positive and negative convergence values reach 61.22 and- 57.69 mm, respectively. Besides, the maximum segment misalignment is 3.67 mm, which occurs in the direction of 90 degrees. The segment cracks when its maximum convergence value reaches 25.03 mm. Moreover, there are signs of fracturing on the waist joint of the segment when its maximum convergence value reaches 32.73 mm. The concrete at the waist joint starts fracturing in pieces when the segment's maximum convergence value reaches 38.93 mm, which is defined as the type of shear failure. Finally, the bearing capacity of shield tunnels during segment failure period can be evaluated by using the corresponding relationship between deformation and internal force.