The Influence of Flooding Water Level on Cooling Limit of RPV Outer Wall under ERVC Conditions

Jialu Qin,Pengfei Liu,Bo Kuang,Kemei Cao,Kun Zhang
DOI: https://doi.org/10.1299/jsmeicone.2019.27.1465
2019-01-01
Abstract:External reactor vessel cooling (ERVC) is considered as one of the most promising severe accident mitigation strategies for an in-vessel corium retention(IVR). When a molten corium is relocated in the lower head of reactor vessel , the external reactor vessel cooling will be activated automatically as the coolant is supplied into the reactor cavity which is a annual gap between the external reactor vessel and the insulation designed for the external reactor vessel cooling to remove the heat of external vessel through the two-phase natural circulation flow. When the severe accident happened, the heat generated by the molten corium will accumulate in the lower head of reactor, in order to improve the margin of in-vessel reactor retention(IVR), the CHF of lower head of reactor must be improved. CHF on different angles will be different basing on various water levels. Flooding water level have a significant impact on the natural circulating ability and CHF of RPV outer wall. A large scale facility ,REPEC-II, has been built to investigate the flow characteristic and CHF under ERVC conditions. This paper will focus on the experimental effect of flooding water level on the natural circulation characteristics and critical heat flux.
What problem does this paper attempt to address?