ICONE19-43196 Prediction of Periodic Dryout Critical Heat Flux under Flow Oscillation Condition

D.W. Zhao,G.H. Su,Z.H. Liang,Y.J. Zhang,S.Z. Qiu
DOI: https://doi.org/10.1299/jsmeicone.2011.19._icone1943_75
2011-01-01
The Proceedings of the International Conference on Nuclear Engineering (ICONE)
Abstract:The transient critical heat flux experiments with forced sinusoidal inlet flow oscillation have been conducted in a vertical tube. The experimental range was as follows: the system pressure P=0.5〜3.0MPa, the averaged inlet mass flux G_=90〜200kg/m^2s, the inlet subcooling T_=55℃, normalized amplitude of flow oscillation ΔG_x/G_=0〜3.0, and oscillation period =1.04, 2.1, 5.2sec. The analysis on parametric trends of normalized oscillation amplitude, oscillation period, pressure and averaged inlet mass flux on normalized periodic dryout critical heat flux, F_p show that: the F_p declines remarkably and tends to a reduction limit, F_ , with an increase of ΔG_/G_; the F_ decrease with an increase of oscillation period τ and averaged inlet mass flux, G_, respectively; the pressure has no obviously effects on the decrease of F_p in 0.5〜3.0MPa. A normalized oscillation period, τ/t_, was introduced to built a correlation of the reduction limit of periodic dryout, F_. Based on the F_ correlation and the analysis of parametric trend, a semi-empirical correlation was proposed to predict the F_p under flow oscillation condition in vertical tubes. The comparisons between the prediction of the new correlation and experimental data show a reasonable agreement.
What problem does this paper attempt to address?