Fast and Simultaneous Detection of Dissolved BOD and Nitrite in Wastewater by Using Bioelectrode with Bidirectional Extracellular Electron Transport.

Shaoan Cheng,Zhufan Lin,Yi Sun,Huahua Li,Xiangrong Ren
DOI: https://doi.org/10.1016/j.watres.2022.118186
IF: 12.8
2022-01-01
Water Research
Abstract:Timely and simultaneously detecting BOD and nitrite concentrations is of great significance for curbing of water pollution and adjusting wastewater treatment strategies. However, existing BOD and nitrite biosensors cannot perform synchronous detection due to their single electroactivity and differences in detection time. This study reported a novel dual-function electrochemical biosensor (DFEB) that could perform fast, simultaneous detection of nitrite and dissolved BOD. DFEB conducted a potential-step chronoamperometry on the mixed-bacteria bioelectrode with bidirectional electron transfer ability to obtain response signals. DFEB accurately measured dissolved BOD in the range of 5 - 100 mg BOD L-1 and nitrite in the range of 0.05 - 16 mg NO2- -N L-1 within 20 min and maintain stable performance over 200 tests. DFEB performed well in artificial wastewater, aquatic wastewater, anaerobic tank effluent and anammox effluent, with relative errors < 15.7% and 16.8% in detecting nitrite and dissolved BOD, respectively. Our study provided a feasible way to develop multifunctional biosensors for detecting pollutants with different redox properties in wastewater.