Preliminary application of 3D-intelligent structured light registration in robot-assisted neurosurgical operations

张凯,吴德龙,刘钰晔,刘德峰,范世莹,刘焕光,张华,杨岸超,张建国,胡文瀚
DOI: https://doi.org/10.3760/cma.j.cn112050-20210429-00207
2021-01-01
Abstract:Objective:To investigate the accuracy and safety of 3D-intelligent structured light registration in robot-assisted neurosurgical operations.Methods:A retrospective analysis was conducted on the data of 77 patients admitted to the Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University from August 2020 to January 2021. All patients underwent neurosurgical robot-assisted surgery based on 3D-intelligent structured light registration; 70 of them underwent stereotactic biopsy, 1 underwent cyst puncture and Ommaya reservoir placement, 1 underwent stereoelectroencephalography (SEEG) electrode placement, and 5 underwent navigation-assisted positioning of intracranial lesion. Through the fusion of postoperative head CT and preoperative surgical planning images, the registration error and the error of the skull entry point were analyzed to evaluate the accuracy of its positioning, and the difference between the registration based on CT and the registration based on MRI was compared. The occurrence of postoperative complications was documented.Results:All 77 patients completed the structured light registration within 2 minutes. The registration error of 27 patients based on CT was 0.18±0.03 mm (0.13-0.23 mm), and the registration error of 50 patients based on MRI was 0.38±0.09 mm (0.15-0.52 mm), the difference between the two was statistically significant ( P<0.01). The error of the skull entry point based on MRI was 1.30±0.78 mm (0.19-3.28 mm), and the error of the skull entry point based on CT was 1.62±1.05 mm (0.29-3.27 mm), the difference between the two was not significance ( P=0.29). Among them, the error of the six skull entry points in 1 case of SEEG operation was 0.98±0.51 mm (0.32-1.74 mm). There were no deaths after surgery, bleeding events related to surgery, intracranial infection or poor healing of surgical incisions, etc. Conclusions:Preliminary research has indicated that the application of 3D-intelligent structured light registration and positioning technology to neurosurgical robotic surgery has the advantages of short registration time, small positioning error, and good safety. Compared with MRI-based registrants, CT-based registration errors are smaller, while their errors of skull entry points seem similar.
What problem does this paper attempt to address?