An Inter-Turn Short-Circuits Fault Detection Strategy Considering Inverter Nonlinearity and Current Measurement Errors for Sensorless Control of SPMSM

Yongxiang Xu,Yangrui Wang,Jibin Zou
DOI: https://doi.org/10.1109/tie.2021.3125653
IF: 7.7
2021-01-01
IEEE Transactions on Industrial Electronics
Abstract:Aiming at the misdiagnosis problem of the interturn short-circuit (ITSC) fault detection method caused by the inverter nonlinearity and the current measurement errors, a d-axis residual voltage-based fault diagnostic strategy is proposed for sensorless control of the surface permanent magnet synchronous motor (SPMSM). The model of the three-phase wye-connected SPMSM with ITSC fault is established, and the expression of the d-axis residual voltage caused by the ITSC fault, the inverter nonlinearity, the current measurement errors and the motor parameter errors is derived. The proposed fault diagnostic strategy can eliminate the current relative gain coefficient error and locate the ITSC fault by using the eighth and second harmonics of the estimated d-axis residual voltage, respectively. The experimental results verify the effectiveness of the proposed fault diagnostic strategy.
What problem does this paper attempt to address?