Seismic analysis considerations for uplifted storage tanks

A. Boccaccini,M. Petitmermet,E. Wintermantel,J. Koenig,C. K. Chang,D. Mao,J. Wu,Y. Goto,H. Ishida,T. Fujisawa,Fain-Seramikkusu
2011-01-01
Abstract:The objectives of this paper are to highlight the principal effects of base uplifting on the seismic response of ground supported cylindrical steel tanks that are unanchored at their Base. In practice, however, complete anchorage is not economical or may not be warranted for certain class of tanks; as a result, many existing tanks are unanchored and may uplift during ground shaking. Base uplifting completely changes the dynamic characteristics such as the stiffness and energy dissipation capacity of the system. The dynamic response of the system also becomes highly non-linear. Studies of the performance of uplifting tanks during past earthquakes have revealed that such systems are prone to extensive damage due to: (i) buckling of the tank wall, caused by large compressive stresses; (ii) rupture at the plate-shell junction, caused by excessive plastic yielding; and (iii) failure of the piping connections to the wall that are incapable of absorbing large base uplifts.