Seismic analysis of a large base-isolated liquid storage tank with fixed roof based on added mass method

ZHANG Zhao-long,GAO Bo-qing,YANG Hong-kang
DOI: https://doi.org/10.3969/j.issn.1000-3835.2012.23.006
2012-01-01
Abstract:The simplified one-dimensional Haroun-Housner model was used widely in seismic isolation study of liquid storage tanks.A simplified three-dimensional mechanical model was established on the basis of added mass method,considering liquid convective and impulsive masses.Validity of the model was verified with dynamic responses of Haroun-Housner model and fluid-solid coupling model under same seismic excitations.Using the model,nonlinear seismic response of a large base-isolated liquid storage tank with fixed roof and friction pendulum system(FPS) bearing was studied systematically under different site conditions.Results showed that FPS isolation bearing is effective in controlling the seismic response of the liquid storage tank,it decreases liquid impulsive motion and avoids the buckling failure of the tank shell,but increases liquid convective motion.
What problem does this paper attempt to address?