ADC Link Capacitors' Voltage Balancing Method in Unidirectional Cascaded H-Bridge Converter Using Multi-limb-core (MLC) Transformer

Zihang Xiang,Muhammad Mansoor Khan,Umar Khalid,Jianming Xu
DOI: https://doi.org/10.1109/cieec.2017.8388517
2017-01-01
Abstract:The DC-DC modular cascaded H-bridge topology is being employed in high-/medium-voltage dc grids. The primary problem that may arise in modular converters is capacitor voltage unbalance which may cause module failure. This paper presents a modular cascaded H bridge with transformer isolated DC-DC converter which operates at synchronized half duty cycle. The converter is isolated by a multi-limb-core (MLC) transformer. A control-free and reliable balancing method for capacitors' voltage is proposed. The mechanism of the balancing method has also been presented. Simulation and experimental results are provided as a verification to the feasibility of the proposed voltage balancing method.
What problem does this paper attempt to address?