Wet gas measurements of long-throat Venturi Tube based on forced annular flow

Weibiao Zheng,Ruomiao Liang,Xingkai Zhang,Ruiquan Liao,Dong Wang,Lamei Huang
DOI: https://doi.org/10.1016/j.flowmeasinst.2021.102037
IF: 2.42
2021-01-01
Flow Measurement and Instrumentation
Abstract:A wet gas dual-parameter measuring device composed of a cyclone and a long-throated Venturi tube is proposed to overcome the difficulty of measuring the liquid content of wet gases and reduce the error caused by the wet gas flow pattern. The flow pattern is transformed into an annular flow by a cyclone. In this study, the proposed device was compared with a traditional non-cyclone long-throat Venturi tube; furthermore, the pressure difference ratio W between the contraction and expansion sections of the long-throat Venturi tube was introduced as a parameter. Through numerical simulations, the relationship between W, the gas Froude number, over-reading, and liquid-gas mass flow ratio was analyzed, and a new wet gas flow measurement model was established. The reliability of the measurement model was verified through indoor experiments. The experimental results showed that the traditional wet gas measurement device had gas phase and liquid phase errors of ±4.5% and ±10%, respectively; on the other hand, the cyclone-based wet gas measurement device had gas phase and liquid phase errors of ±3% and ±8%, respectively. Thus, the performance of the wet gas measurement device with the cyclone was higher than that of the traditional wet gas measurement device.