Wet gas flow modeling for a vertically mounted Venturi meter

Lijun Xu,Wanlu Zhou,Xiaomin Li
DOI: https://doi.org/10.1088/0957-0233/23/4/045301
IF: 2.398
2012-01-01
Measurement Science and Technology
Abstract:Venturi meters are playing an increasingly important role in wet gas metering in natural gas and oil industries. Due to the effect of liquid in a wet gas, the differential pressure over the converging section of a Venturi meter is higher than that when a pure gas flows through with the same flow rate. This phenomenon is referred to as over-reading. Thus, a correction for the over-reading is required. Most of the existing wet gas models are more suitable for higher pressure (> 2 MPa) than lower pressure (< 1 MPa). Much attention has been paid on higher quality (> 0.5) than lower quality (< 0.5) in recent years. However, conditions of lower pressure and lower quality also widely exist in the gas and oil industries. By comparing the performances of eight existing wet gas models in low-pressure range of 0.26-0.86 MPa and low-quality range of 0.07-0.36 with a vertically mounted Venturi meter of diameter ratio 0.45, de Leeuw's model was proven to perform best. Derived from de Leeuw's model, a modified model with better performance for the low-pressure and low-quality ranges was obtained. Experimental data showed that the root mean square of the relative errors of the over-reading was 2.30%.
What problem does this paper attempt to address?