Effect of the Microstructure of a Titanium Alloy Fabricated Using Selective Laser Melting on Microarc Oxidation Film

Wang Haibo,Zhai Dajun,Feng Keqin
DOI: https://doi.org/10.1007/s11661-021-06421-3
2021-01-01
Metallurgical and Materials Transactions A
Abstract:In this study, the effect of the microstructure of a titanium alloy substrate fabricated using selective layer melting (SLM) on a microarc oxidation (MAO) film was studied by comparing it with a forging substrate. The microstructure, thickness, and composition of the MAO coating obtained on the different substrates were detected by scanning electron microscopy, a coating thickness meter, energy-dispersive spectroscopy, and X-ray diffraction, respectively. The corrosion behavior of the MAO coating was evaluated using potentiodynamic polarization tests. The results showed that the SLM substrate presented a dense microstructure composed of fine acicular martensite α ′ and coarse α phases, which included many defects such as dislocations, twins, and grain boundaries. The microstructure supplied many discharge channels, allowing electrons and anions to pass easily, thus reducing the breakdown voltage of the anode oxide film. It also significantly improved the voltage increase rate of the MAO film in the range of 600 to 1800 seconds and decreased the difficulty of microarc nucleation. The SLM-MAO film was thicker than the Forging-MAO film, and the TiO 2 amorphous region of the SLM-MAO film was uniform. Moreover, many P elements were present in the SLM-MAO film. After MAO treatment, the SLM-MAO film exhibited better corrosion resistance.
What problem does this paper attempt to address?