The Modified Z-Epicanthoplasty-A Stepwise and Individualized Design.
Dongze Lyu,Yunbo Jin,Lei Chang,Hui Chen,Gang Ma,Wenxin Yu,Mathias Tremp,Xiaoxi Lin
DOI: https://doi.org/10.1097/SAP.0000000000000781
2017-01-01
Annals of Plastic Surgery
Abstract:PURPOSE:To describe a medial epicanthoplasty technique using a stepwise, customized design and to review the outcome in Asian patients after the treatment of medial epicanthal fold.
DESIGN:Retrospective, noncomparative and interventional case series with the introduction of a new surgical technique.
PARTICIPANTS:Forty-eight consecutive Asian patients with primary medial epicanthal fold.
METHODS:Patient charts were reviewed from patients (mean age, 24.6 ± 3.8 years; range, 19-40 years) with a stepwise z-epicanthoplasty. The intercanthal distance (ICD), interpupillary distance (IPD), and scar visibility were evaluated at regular intervals (preoperative, immediate postoperative, 3 months, 6 months, and 1 year after the operation). The ratio of the ICD to IPD (ICD ratio) was calculated, and the visibility of the surgical scar assessed.
MAIN OUTCOME MEASURES:Postoperative improvement in ICD ratio and scar quality.
RESULTS:The preoperative median ICD ratio was 0.60 (range, 0.57-0.66) and decreased to 0.57 (range, 0.52-0.60) postoperatively. The median ICD ratio reduction was 5.6% (range, 2.6-14.1%; P < 0.001, Wilcoxon signed-rank test). Forty patients (83.3%) had no visible scarring or scarring only visible under close inspection. Eight patients (16.7%) experienced a more apparent scar, but none of them developed a severe scar requiring revision.
CONCLUSIONS:The modified z-epicanthoplasty using a stepwise design is a customized and effective technique for the treatment of the epicanthal fold. This method has a short learning curve, is widely applicable to various types of epicanthal fold, and has a high satisfaction rate with a stable long-term result.