Abstract:To investigate microseismic characteristics of fault activation and its deformation mechanism during the excavation of the underground powerhouse, Microseismic (MS) monitoring technique and field survey was adopted. In this paper, the spatiotemporal distribution of microseismicity of fault activation is summarized and presented. In addition, deformation mechanism of fault rupture was revealed during different stages of excavation, and the results showed that fault propagation was associated with excavation and supporting of the first layer of main powerhouse, tensile fracture was main failure mode in this phase. Then, the fault got into the state of rapid unstable propagation in the initial period of stress adjustment before a steady state was realized. Excavation of the second or third layer of main powerhouse was related to fault movement and the degree of fault activation was slight in these two stages.