Lifetime Measurement Of The T = 23537 Cm-1, J=9/2 Odd-Parity Level In Nd-Ii Using Time-Resolved Collinear Fast-Beam Laser Spectroscopy

W Shi,Fq Lu,Sm Wu,Px Shi,Jj Yang,Lg Song,Jy Tang,Fj Yang
IF: 2.971
1991-01-01
Physical Review A
Abstract:Time-resolved collinear fast-beam laser spectroscopy has been used to measure the lifetime of the T = 23,537 cm-1, J = 9/2 odd-parity [abbreviated as (23 637)9/2-degrees] level in Nd II. Nanosecond pulsed excitation was achieved with the Doppler switching technique. The fast ions were selectively excited from the metastable 4f(4)5d6K9/2 level to the (23 537)9/2-degrees level by the light of a cw dye laser. The decay of the resonance fluorescence photons emitted in the transition to the ground 4f(4)6s 6I7/2 level, as a function of the flight distance, was observed. The decay length was scaled into the decay time by the ion velocity, which was determined using the optical resonance itself. The lifetime is 27.7(9) ns.