Lead-Free Ultrasonic Phased Array Transducer for Human Heart Imaging

Xiaowen Ma,Yingchun Liu,Jiaji Ruan,Chenyang Tao,Jianren Yuan,Yunfei Chang,Wenwu Cao
DOI: https://doi.org/10.1109/TUFFC.2021.3121086
2022-01-01
Abstract:Substantial advancement has been made in recent years on lead-free piezoelectric materials, but up to date, it is still a challenge to make a true medical imaging ultrasonic array transducer with center frequency <3 MHz. There are two major obstacles: the difficulty of fabricating large enough uniform lead-free piezoelectric materials with high piezoelectric coefficient, and the severe electrical impedance mismatch of an array element to the imaging system due to the relatively low dielectric constant of lead-free materials compared to lead-based piezoelectric materials. We resolved these two issues by employing texture engineering and stacking piezoelectric-layer design, which allowed us to fabricate an 80 element phased array transducer with the center frequency of 2.9 MHz and a bandwidth >80% for human heart imaging. The high-quality lead-free (Ba <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0.95</sub> Ca <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0.05</sub> )(Ti <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0.94</sub> Zr <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">0.06</sub> )O <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> textured ceramic plate has the size of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$23\times 22\times0.8$ </tex-math></inline-formula> mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> with the piezoelectric constant <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${d}_{{33}} =570$ </tex-math></inline-formula> pC/N. Phantom imaging and internal clinical human heart imaging demonstrated that this lead-free phased array can produce comparable imaging quality to that of a commercial PZT-5H ceramic-based phased array transducer, which demonstrated the practicality of using lead-free materials to replace PZT ceramics in phased array transducers for medical imaging applications.
What problem does this paper attempt to address?