A Safe and Effective Anastomotic Technique for Robot-Assisted Minimally Invasive Oesophagectomy: Reverse-puncture Anastomosis

Hao Peng,Yi Yang Liu,Maimaitijiang Aimudula,Rong Chun Wang,Hao Chen,Xiaolong Liu,Haizhu Song,Jun Yi
DOI: https://doi.org/10.1002/rcs.2336
2021-01-01
International Journal of Medical Robotics and Computer Assisted Surgery
Abstract:Background Oesophagogastric anastomosis is mainly complicated by its tediousness. We hope to modify an oesophagogastric anastomotic technique that simplifies anastomosis. Methods We conducted a retrospective analysis of 57 cases executed using reverse-puncture anastomotic (RPA) technique and 64 cases of manual purse anastomosis (MPA) technique for robot-assisted minimally invasive oesophagectomy (RAMIE). Baseline characteristics and perioperative outcomes were analysed. Results There were no significant differences between the 2 groups with regards to demographic data and clinical features. All patients had R0 resection. Relative to MPA, RPA group experienced significantly shorter operation times (232.5 +/- 33.84 min vs. 262.3 +/- 83.94 min, p = 0.038).RPA group patients had shorter anastomotic times relative to MPA group patients (10.5 +/- 3.4 min vs. 18.3 +/- 4.1 min, p = 0.014). No adverse events were observed. Conclusions Reverse-puncture anastomosis is safe, feasible in RAMIE. This approach has the potential to efficiently shorten the anastomotic time and ensure safe operation.
What problem does this paper attempt to address?