[Combining Different Aerobic/Anoxic Durations with Zoned Sludge Discharge to Optimize Short-cut Nitrification Denitrifying Phosphorus Removal Granules in Domestic Sewage].

Wen-Qi Wang,Dong Li,Xin Gao,Jie Zhang
DOI: https://doi.org/10.13227/j.hjkx.202102182
2021-01-01
Abstract:In this study, domestic sewage was used to inoculate mature short-cut nitrification denitrifying phosphorus removal particles, which were cultivated and matured under artificial water. The operation of the short-cut nitrification denitrifying phosphorus removal system was optimized using different aerobic/anoxic durations combined with zoned sludge discharge. The results showed that regulating the aerobic/anoxic duration, in combination with zoned sludge discharge, can realize the stable operation of the system. In the later stable period, the effluent COD concentration was below 50 mg·L-1, the effluent TN concentration was below 15 mg·L-1, the TN removal rate reached about 83% and remained stable, the effluent P concentration was below 0.5 mg·L-1, and the average P removal rate was 93.72%. At the same time, zoned sludge discharge (70% top sludge and 30% bottom sludge) can be used to screen out microorganisms, maintain good nitrosation and phosphorus removal performance, limit the particle size distribution, and ensure the growth advantages of AOB and DPAOs. Increases in the anoxic duration improved the growth rate of anoxic heterotrophic bacteria, causing them to secrete more EPS and ensuring granular sludge improvements and continued stability.
What problem does this paper attempt to address?