Aerobic Granular Sludge Treating Low-Strength Municipal Wastewater: Efficient Carbon, Nitrogen and Phosphorus Removal with Hydrolysis-Acidification Pretreatment.

Cheng Yu,Kaijun Wang,Chen Tian,Quan Yuan
DOI: https://doi.org/10.1016/j.scitotenv.2021.148297
IF: 9.8
2021-01-01
The Science of The Total Environment
Abstract:Low organic load while high fraction of particulates still challenging the application of aerobic granular sludge process in low-strength municipal wastewater treatment. The feasibility of adopting short cycle length to increase organic load and hydrolysis-acidification pretreatment to enhance anaerobic COD uptake was evaluated. As the cycle length decreased from 4 h to 2 h, the organic loading rate increased from 0.98 to 1.3 g L−1 d−1 and granulation appeared after two weeks. Moreover, with the hydrolysis-acidification pretreatment, the average effluent TN and TP concentrations decreased respectively from 17.8 to 13.7 mg L−1 and 0.76 to 0.41 mg L−1, meeting the Grade IA of the effluent standards in China. Furthermore, cycle tests were conducted to reveal the underlying mechanism of the pretreatment effects. The results showed that the hydrolysis-acidification pretreatment enhanced the COD storage and phosphorus release in anaerobic phase, and improved the simultaneous nitrification-denitrification process, as well as the phosphorus uptake in aeration phase.