Effect of rt‐PA on Shear Wave Mechanical Assessment and Quantitative Ultrasound Properties of Blood Clot Kinetics In Vitro

Guillaume Bosio,François Destrempes,Marie‐Hélène Roy Cardinal,Guy Cloutier
DOI: https://doi.org/10.1002/jum.16411
2024-01-13
Journal of Ultrasound in Medicine
Abstract:Objective The consequences associated with blood clots are numerous and are responsible for many deaths worldwide. The assessment of treatment efficacy is necessary for patient follow‐up and to detect treatment‐resistant patients. The aim of this study was to characterize the effect of treatment on blood clots in vitro using quantitative ultrasound parameters. Methods Blood from 10 pigs was collected to form three clots per pig in gelatin phantoms. Clots were subjected to 1) no treatment, 2) rt‐PA (recombinant tissue plasminogen activator) treatment after 20 minutes of clotting, and 3) rt‐PA treatment after 60 minutes of clotting. Clots were weighted before and after the experiment to assess the treatment effect by the mass loss. The clot kinetics was studied over 100 minutes using elastography (Young's modulus, shear wave dispersion, and shear wave attenuation). Homodyne K‐distribution (HKD) parameters derived from speckle statistics were also studied during clot formation and dissolving (diffuse‐to‐total signal power ratio and intensity parameters). Results Treated clots loosed significantly more mass than non‐treated ones (P
radiology, nuclear medicine & medical imaging,acoustics
What problem does this paper attempt to address?