A Calibration Ultrasound Method to Estimate Contact Characteristics at Spindle-Holder Interface

Qiang Li,Yuan-yuan Zhang,Shi-wei Liang,Fei Qiu,Fei Du,Zhao-hui Yang
DOI: https://doi.org/10.1109/spawda51471.2021.9445451
2021-01-01
Abstract:Contact parameters of a spindle-holder interface have great influence on the performance of the precision machine tool. However, it is hard to experimentally evaluate the contact parameters. In this paper, a calibration ultrasound method is proposed for contact characteristics measurement of actual 7:24 spindle-holder taper interface. The reflection coefficient of BT 40 type taper interfaces is measured by ultrasonic scanning. A calibration equation is used for contact pressure estimation, and a stiffness calibration equation is further used for contact stiffness estimation. The result was validated by an impact hammer testing. The results show that the surface shape error has a great effect on the contact pressure. The model based on the contact stiffness measured by the presented method can be effectively used to predict the dynamics of spindle system.
What problem does this paper attempt to address?