Mercury removal from spent low‐level mercury catalyst by thermal treatment

Chao Liu,Jian Liu,Ping Guo,Jinhui Peng,Libo Zhang,Yaping Li
DOI: https://doi.org/10.1002/CJCE.24122
2021-01-01
Abstract:Spent low-level mercury catalyst (SLMC) from the polyvinyl chloride industry is a mercury-containing hazardous waste. Thermal treatment technology was used to detoxify SLMC and recover mercury in this paper. Effects of flow rate of nitrogen, treatment temperature, and time on mercury removal efficiency were estimated 99.91% of total mercury was removed when SLMC was treated at 600 degrees C for 30 min with 120 L/h of nitrogen. SLMC could be detoxified after being treated at 350 degrees C for 120 min, 400 degrees C for 60 min, or 450 degrees C for 10 min based on the TCLP test. Migration rule of mercury during thermal treatment was analyzed by using improved sequential extraction procedure. Soluble and exchangeable mercury, and mercury combined with labile organics, were removed more easily than HgS and mercury combined with non-labile organics. Removal process of total mercury followed a first-order kinetic model. The experimental results may be useful for disposing of SLMC using thermal treatment in engineering practise.
What problem does this paper attempt to address?