A Directional Coupler with Corrugated Waveguide and Wire Array for 330 GHz DNP-NMR System

Xing-Chen Yang,Chao-Hai Du,Zi-Chao Gao,Feng-Yuan Han,Shi Pan,Pu-Kun Liu
DOI: https://doi.org/10.1109/ICMMT49418.2020.9386338
2020-01-01
Abstract:High power and frequency stability of electromagnetic wave input are required in the DNP-NMR system. It is necessary to monitor the electromagnetic wave energy in the transmission line in real-time to judge the magnitude and stability of the energy transmitted to the NMR spectrometer. However, the energy in the transmission system is too large to be directly measured in the transmission line. A part of the energy must be extracted to facilitate the measurement. We design a directional coupler by placing a wire array in the middle of the three-port circular corrugated waveguide for real-time extraction of transmitted energy. In the frequency range of 290 - 360 GHz, 0.05% energy can be stably coupled to port 3, so it is convenient for the energy detection. The S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">11</sub> parameter of the designed directional coupler can below -20dB from 290 to 360 GHz, and even -41dB at the operating frequency of 330 GHz.
What problem does this paper attempt to address?