Hexafluorophosphate Intercalation into Graphite Electrode from Propylene Carbonate/methyl Acetate Solutions

Dandan Zhu,Hongyu Wang
DOI: https://doi.org/10.1016/j.electacta.2021.138108
IF: 6.6
2021-01-01
Electrochimica Acta
Abstract:The electrolyte solutions based on binary solvent mixtures have shown considerable promise in dualion batteries. In order to make the best use of advantages of both propylene carbonate (PC) and methyl acetate (MA), LiPF6-PC and MA solutions are mixed together to pursue an optimized performance of anion storage in graphite electrode. The electrochemical behavior of PF6- storage in graphite has been studied in 1 M LiPF6 PC/MA solutions by galvanostatic charge-discharge test, in-situ or ex-situ measurements. On the other hand, the solutions have been characterized by FTIR and NMR to assess the interactions between ions and solvents. The underlying mechanisms have been explored. (C) 2021 Elsevier Ltd. All rights reserved.
What problem does this paper attempt to address?