1/ f -noise-free optical sensing with an integrated heterodyne interferometer

Ming Jin,Shui-Jing Tang,Jin-Hui Chen,Xiao-Chong Yu,Haowen Shu,Yuansheng Tao,Antony K. Chen,Qihuang Gong,Xingjun Wang,Yun-Feng Xiao
DOI: https://doi.org/10.1038/s41467-021-22271-4
IF: 16.6
2021-01-01
Nature Communications
Abstract:Optical evanescent sensors can non-invasively detect unlabeled nanoscale objects in real time with unprecedented sensitivity, enabling a variety of advances in fundamental physics and biological applications. However, the intrinsic low-frequency noise therein with an approximately 1/ f -shaped spectral density imposes an ultimate detection limit for monitoring many paramount processes, such as antigen-antibody reactions, cell motions and DNA hybridizations. Here, we propose and demonstrate a 1/ f -noise-free optical sensor through an up-converted detection system. Experimentally, in a CMOS-compatible heterodyne interferometer, the sampling noise amplitude is suppressed by two orders of magnitude. It pushes the label-free single-nanoparticle detection limit down to the attogram level without exploiting cavity resonances, plasmonic effects, or surface charges on the analytes. Single polystyrene nanobeads and HIV-1 virus-like particles are detected as a proof-of-concept demonstration for airborne biosensing. Based on integrated waveguide arrays, our devices hold great potentials for multiplexed and rapid sensing of diverse viruses or molecules.
What problem does this paper attempt to address?