Abstract:Objective To study the feasibility of ultrasound-guided prelocation for right internal jugular vein (IJV) cannulation. Methods Fifty-three patients with general anesthesia requiring internal jugular vein catheterization were randomly divided into two groups. Group A (ultrasound localization before puncture) used two-dimensional ultrasound to mark the middle point of internal jugular vein at the level of thyroid cartilage, and then guided deep vein puncture and catheterization according to the puncture point and course. Group B (puncture and ultrasound guidance) guided the puncture needle into the vein under ultrasound imaging. The number of puncture, puncture catheter time and complications were recorded. Quantitative data were compared by independent sample t test, and counting data were compared by χ2test and Fisher exact probability method. Results In group A, 4 cases were punctured twice, 5 cases were punctured three times, one of them had hematoma; in group B, 2 cases were punctured twice, no complications occurred. The number of punctures between the two groups was statistically significant (P < 0.05). There was no significant difference in the puncture time between group A and group B [(5.57±1.42) min vs. (5.87±1.45) min)] (P>0.05). Conclusion Ultrasound-guided prelocation for right internal jugular vein cannulation is feasible.