Study on Treatment of Wastewater by Bio-film Using Hollow Fiber Membrane As Carrier and Bubbleless

ZHANG Feng-jun,DU Xiang-jun,ZHAO Zhi-qing,WANG Shuang,HU Si-xian
DOI: https://doi.org/10.3969/j.issn.1671-5888.2005.02.018
2005-01-01
Abstract:Hollow fiber membrane was used as bio-film carrier and bubbleless device in the wastewater treatment experiment. The experiment also made use of submerged contact oxygenation technique,which had dead-end and floating merits. The results showed that the removal ratio of COD, BOD and SS was 70%, 90% and 75% respectively when working pressure was 0.03 MPa, DO was 5~8mg/L and HRT was 8 h in the system. Study also showed that the removal ratio of NH_3-N, P was more than 70%. The system has better stability and resistence to substrate flux after three months of continuous running.
What problem does this paper attempt to address?