Hot behavior of supercritical martensitic stainless steel at elevated temperature

WANG Menghan,WANG Rui,WANG Gentian,MENG Lie
DOI: https://doi.org/10.11817/j.issn.1672-7207.2017.06.006
2017-01-01
Abstract:Isothermal hot compression tests of supercritical martensitic steel were performed on a Gleeble-3500 thermo-mechanical simulator at the temperature range of 900-1 150 ℃ and the strain rate range of 0.005-5 s-1 to obtain the flow stress-strain curves.Based on the experimental data,modified constitutive models were developed,and the suitability of Johnson-Cook (JC) and Arrhenius flow stress models to the studied steel was discussed.The results indicate that the modified constitutive models are more accurate in predicting the flow stress.The modified JC model is more accurate under high strain rate conditions,while the Arrhenius model is more accurate at low strain rate conditions.The values of experimental load and predicted load show a good agreement,indicating that the developed model is adequate to describe the flow behavior of the steel.
What problem does this paper attempt to address?