The information fusion method in the system of water content measurement in heavy oil

罗桂娥,杨欣荣,凌玉华,刘连浩,孙克辉
DOI: https://doi.org/10.3969/j.issn.1672-7207.2001.03.027
2001-01-01
Journal of Central South University of Technology
Abstract:In the system of water content measurement in heavy oil, radio frequency capacitance sensors are adopted based on the principle that the dielectric constant of water is far greater than that of heavy oil,and thus the reflected specific properties are different in the respect of radio frequency impedance. But duo to the cross sensitivity of sensors to temperature, the authors explore how to employ the information fusion method in the melting processing the input and output information of sensors to improve the measuring precision of the target parameter and the temperature stability of the measuring system. There are many methods to melt two kinds of information. The authors have adopted the method of curved surface fitting. Based on sensors′ property tests by using lubricant, the results show that the sensitive temperature coefficient successively is 4.01×10 -3 , 3.56×10 -3 , 3.53×10 -3 and 3.30×10 -3 /℃ before information fusion processing, when the water contents were labeled as 0%, 3%, 8% and 10%. But after information fusion processing, it is 1.06×10 -3 , 2.43×10 -3 , 8.66×10 -4 and 8.50×10 -4 /℃. Both the temperature stability and the measuring precision improved greatly compared with that before melting processing.
What problem does this paper attempt to address?