A Novel Fuzzy Fusion Method Based Deviation and Its Application on Furnace

黄翼虎,周泽魁,李保国,张银萍
DOI: https://doi.org/10.3969/j.issn.1004-1699.2004.04.023
2004-01-01
Abstract:In order to improve performance on security, stability and accuracy of oil outlet temperature in the direct furnace, a novel fuzzy fusion method based on the deviation is proposed. The direct furnace is a dynamic system, which input multiple-variables and output miltiple-variables are strong-coupled. Based on the furnace features. the improved fuzzy method uses the deviation of some correlative parameters that acquired from furnace as input parameters, which thinks over possibility of sensors fault. Then the change of the trend of furnace can be gotten. which is used to identify faulty sensors in the furnace and fire-nozzle deflection. The sensors precision. asymmetric flow of two oil pipeline and fire-nozzle deflection are also taken into account in the fusion method, thereby the fusion result of oil pipeline. Experimental results indicate that the accuracy of oil outlet temperature can be advanced about 0.5°C. The method can abroad apply to other dynamic system.
What problem does this paper attempt to address?