Magnetic flux leakage testing method study for upset transition zone of drill pipe

Bo Feng,Lujun Ba,Yanhua Sun,Yihua Kang
DOI: https://doi.org/10.13245/j.hust.140503
2014-01-01
Abstract:The magnetic field refraction theory and the corresponding finite element model was carried out to analyze the magnetic field distribution of the upset transition zone .The background magnetic field caused by radius changing and the non-uniformity of magnetization caused by wall thickness changing are the main features of the upset transition zone .Then ,the background field caused by ra-dius changing was confirmed to be the reason for baseline shifting ,and this effect was eliminated by the differentiation method .At the same time ,the non-uniformity of magnetization caused by wall thickness changing was found to be the reason which makes the magnitudes of leakage field different for the defects with same dimension .After analyzing the influence of wall thickness and magnetization on magnetic leakage field ,a deep magnetic saturation method was proposed .The results show that this method can effectively eliminate the background field in the upset transition zone and guarantee the consistency of detection signal ,thus makes the magnetic flux leakage testing method suitable for the inspection of upset transition zone of drill pipe .