Single-ended travelling wave protection scheme based on ratio between earth-module wave and line module wave for HVDC

Min Huang,Zhicheng Xie,Ming Chen,Xiangning Lin
DOI: https://doi.org/10.13245/j.hust.140817
2014-01-01
Abstract:This paper analyzes and studies the problem of fail-to-trip frequently under the condition of faults with high resistance occurring on HVDC line of Tianguang project .It is pointed out that the voltage change ratio together with the voltage magnitude difference under the internal fault with high resistance are lower than those under the condition of external faults ,which leads to the fail-to-trip of the protection .Based on this discovery ,a novel single-ended traveling wave protection scheme based on the ratio between earth module wave and line module wave for HVDC line is proposed in this pa-per .In this scheme ,the fault travelling wave can be decomposed into earth module wave and line module wave by use of Modulus decomposition ,the characteristic of earth module wave under differ-ent fault conditions are analyzed based on PSCAD/EM TDC simulation and calculation platform .The-oretical analysis and simulation results show that the proposed method is able to respond to various in-ternal faults with high resistance and has high sensitivity .It is better than the existing protection scheme .
What problem does this paper attempt to address?