Temperature Field of Mass Concrete Foundation with Pipe-Cooling

Demin Wei,Chuanhai Hong,Chongyang Li,Lisheng Hu
DOI: https://doi.org/10.11784/tdxbz201506005
2016-01-01
Abstract:In this paper,the temperature field of mass concrete foundation was analyzed using the finite element method.In the analyses,the influence of some parameters was considered such as the horizontal and vertical dis-tances of cooling pipes,the difference between concrete input temperature and water inlet temperature,the pipe length,the flow of cooling water,and the thickness of the foundation.A practical calculation formula to estimate the highest temperature of mass concrete block was established by regression analysis,which fits well with the measured data and other numerical results and has a reference value for the construction of mass concrete foundations.The re-sults show that the influence of the distance of cooling pipes and pipe length on the highest temperature of mass con-crete foundation is most evident.
What problem does this paper attempt to address?