Experimental Study on Quadrangular Prism Unit of Tensegrity

CHEN Zhi-hua,SHI Jie,LIU Xi-liang
DOI: https://doi.org/10.3969/j.issn.0493-2137.2005.06.014
2004-01-01
Abstract:In order to obtain structural characteristic of quadrangular prism unit of tensegrity and to make pre- paration for study on assembled large-span tensegrity structures, analysis was made on internal force and displacement of quadrangular prism unit of tensegrity under load by nonlinear finite element method (FEM).Study on structural characteristic under load was made by full size model test in scale of 1∶1 with semispherical joint, which was designed in this study.The curves of load-displacement and load-force under different prestress levels were analyzed.The result of test was consistent with that of the theoretical analysis. Based on that, the relation between prestress and structural stiffness, bearing capacity, as well as the relation between prestress and structural nonlinear feature and characteristic of the first-order stiffness were carried out.