Recording and spectral analysis of lung sound signal before-after sport

Ping LU,Yi-jian MIN,Tie-qun QIAN
DOI: https://doi.org/10.3969/j.issn.1672-4291.2005.03.018
2005-01-01
Abstract:Athletes are always involved in a state of highly lack of oxygen because of training and competition; in such a circumstances, the requirement on athletes′ respiratory system is higher than that of normal persons. Therefore, the study on the spectral variation of the athlete′s lung sound before and after sport can effectively produce the information such as the state of cardiopulmonary function as well as the relationship between the lung sound and the athletic load. The super low frequency air-coupling sensor is applied to measuring the lung sound of the athlete before and after sport. In addition, the commonly used FFT (Fast-Fourier Transform) method is also applied to analyzing the 1 024 dots and Hanning Window. Results: the lung sound variation is great before and after sport; the lung sound between athletes with different events shows great discrepancy. However, the peak frequency and range of athlete′s lung voice is lower than that of the normal person, and the frequency spectral of athletes is higher than that of the normal adult when the total power is at the state of 25% and 50%.
What problem does this paper attempt to address?