Study on Application of Two-Stage Bio-Contact Oxidation Process in Low-Temperature Municipal Waste Water Work

CAO Ji-hong,MA Fang,ZHAO Li-jun,ZHAO Qing-jian
DOI: https://doi.org/10.3969/j.issn.1672-0946.2005.02.009
2005-01-01
Abstract:The feasibility of the treating with low-temperature municipal waste water by two-stage bio-contact oxidation process is discussed, according to the general problems of the low removal rate of low-temperature municipal waste water. The results of engineering application showed that the process had high contaminant removal rate and under the temperature of 8~15 ℃, the COD, BOD5 and SS of outlet were 49.68, 21.62 and 22 mg/L respectively,corresponding the inlet 475.49, 251.69 and 298.67 mg/L,the removal rates reached 89.6% ,91.4% and 92.6% respectively.
What problem does this paper attempt to address?