Abstract:In order to improve the biological activity of micro-arc oxidation coatings on magnesium alloy,four kinds of calcium and phosphorus active material systems were studied in micro arc oxidation.The surface morphology of samples were observed using scanning electron microscope(SEM)and the sample surface ele-ments were analyzed by EDAX.The characteristics of microstructure was expressed using atomic force micro-scope(AFM).The thickness and porosity of coatings were measured.The results showed that the Ca(H2PO4)+NaOH system can successfully prepare the colloidal solution as the electrolyte,which was beneficial to the deposition of calcium phosphorus.When the molar ratio of NaOH and Ca(H2PO4)2was 1:4 and the concentra-tion was respectively(10g/l,6.5 g/l),(15g/l,10g/l)and(20g/l,13g/l),the thickness of the coatings prepared was 5.1 μm,6.3 μm and 8.3 μm,respectively and the porosity of the coatings was 53%,64%and 63%respectively.AFM showed that grain size increased with increasing concentration,and the size of particles coated increased from 358nm to 508nm.The particles nonuniform distribution within the scope of the micro re-gion were found when the concentration of NaOH and Ca(H2PO4)2was 10 g/l and 6.5 g/l,and raised more a-cute.The micropore division was uniform when the concentration increased to 15g/l and 10g/l of NaOH and Ca(H2PO4)2,and the particles was relatively smooth and the number of particles in the micro-region increased.The ration of calcium phosphate increased from 0.17 to 0.25.