Analysis of internal flow field and thermal stress for a purifier based on fluid structure interaction

Yinnan YUAN,Congwei MEI,Zhixin LIU,Deqing MEI,Chen CHEN,Jun TAO
DOI: https://doi.org/10.19411/j.1007-824x.2017.02.012
2017-01-01
Abstract:The internal flow distribution of purifiers with tapered expansion pipe and flared expansion pipe are researched by computational fluid dynamics (CFD).It is revealed that the flow distribution uniformity of tapered expansion pipe is lower than that of the flared expansion pipe.Using the flared expansion pipe can reduce separation between fluid and wall in the diffuser pipe,which can decrease eddy area and turbulent kinetic energy and thus improve the uniformity.Based on numerical simulation of fluid structure interaction,as the chemical reaction is ignored,thermal stress of the shell of purifier is lower and thermal stress mainly focuses on inlet and outlet cone point.The purifier with flared expansion pipe is favorable for improving flow distribution.However,the expansion bassoon turns out larger thermal stress and thermal deformation due to the nonuniform circumferential temperature and large temperature gradient in the inlet straight pipe of the carrier.
What problem does this paper attempt to address?