Assessment of location accuracy by ampl itude-frequency ratio method based on FDTD

Yun LI,Taichang GAO,IANG J,Shuai HU,Wantong LI
DOI: https://doi.org/10.7666/j.issn.1009-3443.20150302001
2016-01-01
Abstract:The detection range and location accuracy of single-station lightning location method was studied. The errors of amplitude-frequency ratio method were analyzed with finite difference-time domain(FDTD). Then,vertical electric fields and magnetic fields of lightning were calculated by the transmission line model (TL),modified transmission line model with liner current decay(MTLL)and modified transmission line model with exponential current decay(MTLE)in different ranges from the lightning channel on the finite conductivity ground.The results of the three models are very similar.To ensure the location error less than 10%,detection range of amplitude-frequency ratio method in the three models is 1 9 ~43 km,17 ~46 km and 9~38 km.When the distance is less than 9km or larger than 46km,the location error is larger than 10% in the three models.Therefore,if the distance between the lightning source and the observation sta-tion is too close or too far away,amplitude-frequency ratio method of single-station lightning location tech-nique is not applicable.
What problem does this paper attempt to address?