Abstract:The main portion of a railway super bridge is a prestressed concrete rigid frame bridge with continuous beam. The total length of three-span is 216m. In this paper, using the three-dimensional photoelastic frozen stress method, the stresses for the pier beam joint structure in the rigid frame bridge with continuous beam were analyzed. The results of boundary stress distribution and principal stress trajectories were given as well. The pier beam joint actual structure was also analyzed with the finite element program ANSYS. After comparing experimental solutions with finite element results, it is shown that the results from experimental stress analyses agree well with the calculated data by using finite element method. In finite element analysis, we studied the influence area of loaded restraint at the end of beam in the joint structure, and find that it is effective to reduce the local stress by choosing appropriate length of beam. The results obtained from the model experiments and the finite element computations are helpful for optimizing the structure design.