Abstract:The fugitive dust concentration measurement method and the system are presented based on light scatter-ing when a single wavelength laser goes through fugitive dust.The system approximates the real particle size distribution by a bimodal normal distribution model and calculates fugitive dust concentration in an opening light-path real-timely. There are a wide dynamic range and a real-time response speed,so it’s appropriate for the measurement of fugitive dust with a high concentration,a fast change and a wide range.The feasibility and reliability is proved by hydrosol experi-ments and smoke dust tests.Experimental results show that the system can cover a concentration measurement range of 0~400mg/m3 with a resolution of 0.05mg/m3 ,and finish a measurement in less than 1s.