Nicarbazin Determination In Feed By Reverse-Phase High Performance Liquid Chromatography

Qj Shao,Jz Zhang,Sr Xuan,Cy Zhu,Hh Chen,Qf Shen,Zr Xu
DOI: https://doi.org/10.3321/j.issn:0253-3820.2003.11.023
IF: 1.193
2003-01-01
Chinese Journal of Analytical Chemistry
Abstract:After extracting by dimethylformamide (DMF), homogenizing and concentrating by using alkaline alumina column, rinsing and fixing volume by lotion,then the nicarbazin in-feed was determined by reversed-phase high performance liquid chromatography with ultraviolet detection at 365 nm, 1 mL/min and C-18 sorbent. By a series of the experiments on comparing alumina activity, alumina column height, and methanol-water ratio, the optimal measurement condition was set as drying alumina with height 6 cm At 105,C for 2 hours under methanol-water ratio 80:20. The verify test was carried out through 30-replication by adding 100 mg/kg nicarbazin in feed., Nicarbazin recovery in feeds was ranged from 91.9% to 107.5% with relative standard deviation 4.0%. There was no interference from coccidiostat salinomycin, maduramasin and diclazuril when nicarbazin in feeds was measured with the method.
What problem does this paper attempt to address?