Determination of zonisamide by a coated monolithic column.

Jing Li,Genfu Wu,Yan Zhu
DOI: https://doi.org/10.1016/j.chroma.2006.02.058
IF: 4.601
2006-01-01
Journal of Chromatography A
Abstract:In this paper, a monolithic ODS-silica gel column dynamically coated with cetylpyridinium chloride (CPC) was used to demonstrate the high-speed and efficient separation of zonisamide (1,2-benzisoxazole-3-methanesulfonamide, ZNS), its raw material (1,2-benzisoxazole-3-methanecarbonic acid) and intermediate (sodium 1,2-benzisoxazole-3-methanesulfonate) in drugs. Using a 40mmol/L sodium perchlorate solution (pH 7.0) containing 10% acetonitrile as eluent, the analytes were eluted with a sharp and symmetrical peak within 3.0min, detected with UV detection at 210nm. The column demonstrates excellent stability over time, and exhibits unusual selectivity for pharmaceutical analysis. Thus, by this developed method, zonisamide in drug samples can be determined rapidly with high recoveries and good selectivity.
What problem does this paper attempt to address?